Skip to main content

A2Trak

Welcome to the City of Ann Arbor, MI

NOTE: This system holds outstanding cases and archival information for permits and plans applied for from ~2008 through March 2022. All new applications must be submitted and managed via stream.a2gov.org.
  • To access digitized microfiche and paper records of permits and projects from ~1930 to 2007 that are larger in printed size, please use the large archived project lookup.
  • To access smaller sized permit documents of digitized microfiche and paper records of permits and projects from ~1930 to 2007, please use the small archived project lookup.
For assistance using this tool please see our Help Guide. If you are having problems using this site please contact the Building Department ([email protected])​ for help.

Permit Information: BLDG12-0515

Applicant: Patrick J Ferrell Type: BUILDING
Subtype: RES ADD/ALTER Description: NEED INSPECTION - WORK DONE BY OTHERW W/O Permit (See Notes)
Status: CANCELLED Applied Date: 04/13/2012
Approved Date: 04/13/2012 Issued Date: 04/13/2012
Finaled Date: Expiration Date: 11/26/2012
Notes: (4/13/2012 1:30 PM BA)
Note: This is rental housing that had a finished basement without permits. They need to have an inspector do a first inspection to see what is NOT up to code, then they can submit revised drawings and FIX the problems.

(4/19/2012 10:01 AM KL)
Provide/verify plumbing, electrical & mechanical permits and inspections for new bedroom, family room, hallway and bathroom.
Provide proper ceiling height at egress stairway per 2009 MRC section R311.7.2.
Provide proper ceiling height in habitable space per 2009 MRC section R305.1.
Provide proper ceiling height at obstructions (currently 5' 10") per 2009 MRC section R305.1.1.
Verify treated sill plates at bottom of new walls.
Verify firestopping at the ceiling line of all new walls per 2009 MRC section R302.11.
Provide code compliant emergency escape & rescue opening, including window well, ladder in new bedroom per 2009 MRC section R310.
Provide light, ventilation and heating per per 2009 MRC section R303..
Provide hard wired interconnected smoke detection system per 2009 MRC section R314.
Provide code compliant handrail per 2009 MRC section R311.7.7.
List incomplete.

Owner: FARROW FREEMAN Address: 1409 E STADIUM BLV
City/State/Zip: Ann Arbor MI 48104 Property Type: PARCEL
Parcel ID: 09-09-33-311-019 Subdivision: FRISINGER LAND COM
Tract: Block:
Lot: Sect-Twp-Rng:
Lot Size (Ft2): Valuation: $500.00

Zoning: R1C Building Size (Ft2): 1,492
Occupant Load: Num Stories:
Num Units: Num Buildings:
Use: Construction Type:
Code: Suppression System:
Alarm System:    
Stipulations: Note: This is rental housing that had a finished basement without permits. They need to have an inspector do a first inspection to see what is NOT up to code, then they can submit revised drawings and FIX the problems.

Loading...
Type Name Address City/State/Zip Phone Email Fax Cell Pager

Loading...
Assessed Date Fee Type Subfee Type Comments Quantity Amount Date Paid Receipt Account

Loading...
Type Reviewer Sent Date Returned Date Due Date Status Remarks Notes

Loading...
Type Inspector Scheduled Date Completed Date Result Duration Remarks Notes

Loading...
Type Number Type Status

Loading...
Date Created File Name